The GE-315 Series Target Water Flow Switch is a new type flow switch, avoilding rust and bad contact by separating the electricity from the liquid. This products totally give up the isolating part for water and electricity by corrugated pipe applied on common target flow switch. When the micro switch is operating, it won’t touch with low temperature metal part, so no condensation water, no rust and bad contact, and the Protection Grade up to IP65, it could be applied in corrosive air environment.
Similar as Sika & Honsberg Flow Switch, but cheap price.
Character:
* Good Repeatability
* Low Pressure Loss
* Dirt Resistant
* Hermetic Separation of Electrical and Hydraulic Components
* Easy Adjustment of Switch
Specification:
* Electricity: Max 250V, Max 5A
* Tolerance ±15% of full scal
* Media Temperature -30~110C
* Average Pressure Loss 0.01bar at Qmax.
* Hysteresis depending on switch value, Minimum 0.7 l/min.
* Metering Substances Oil, Water, Gas, Air(If special substances, please declare)
* Max Pressure 25bar (40bar could be custom-made)
* Protection Grade IP65
* Materials: Stainless Steel or Brass
* Pipe Connection: BSP or NPT , Male or Female thread.
* Wire Connection: hirschman DIN or Cable with sealing
Model
|
Pipe Size
|
Adjustable Range for Flow Setpoint (L/min)
|
1st Range
|
2nd Range
|
3rd Range
|
4th Range
|
5th Range
|
GE-315-G3/8”
|
DN10
|
1.4~2.0
|
2.0~2.6
|
2.4~3.2
|
2.7~3.6
|
3.7~5.0
|
GE-315-G1/2”
|
DN15
|
3.3~4.4
|
4.4~5.9
|
5.3~7.2
|
6.0~8.1
|
8.4~11.3
|
GE-315-G3/4”
|
DN20
|
5.8~7.8
|
7.8~10.6
|
9.4~12.8
|
10.6~14.4
|
14.9~20.1
|
GE-315-G1”
|
DN25
|
9.1~12.3
|
12.2~16.5
|
14.7~19.9
|
16.6~22.5
|
23.2~31.4
|
GE-315-G5/4”
|
DN32
|
14.8~20.1
|
20.0~27.1
|
24.1~32.7
|
27.3~36.9
|
38.1~51.5
|
GE-315-G3/2”
|
DN40
|
23.2~31.4
|
31.3~42.3
|
37.7~51.0
|
42.6~57.6
|
59.5~80.5
|
GE-315-G2”
|
DN50
|
36.2~49.0
|
48.8~66.1
|
59.0~79.8
|
66.8~90.7
|
93.0~125.8
|
* NPT or other thread is available
* The adjustable range is for flow setpoint, not for max flow rate.